The freeze-belt risk system insurers can underwrite.
Hydra watches the line and acts without waiting for someone in the house. Zone protection. Metered freeze without an open faucet. Leak always wins. Every action lands in a log a carrier can see.
The risk carriers already pay
Pipes don’t burst because it’s cold. They burst from pressure behind an ice plug. Hydra is freeze and leak on the same line, decided on the device, written to a log. Physics is the mechanism. Risk transfer is the sale.
Open-faucet advice wastes water
The usual advice is to leave a faucet running. That’s about 3 gallons an hour, 72 gallons a day — and it still doesn’t guarantee the pipe won’t freeze.
One winter claim can wipe a year
State Farm paid more than $628 million on 20,000+ frozen-pipe and winter water claims from 2024 through June 2025 — more than $30,000 a claim, one carrier.
Carriers want proof it’s live
Every condition, zone, and action shows in the app as it happens. That same record is how a carrier can verify Hydra is installed and working.
The arbitration
Freeze and leak on the same line. Leak always wins.
Decisions happen on the device. The app is the record — and what the $50/month monitoring buys. This is not an “alert then shut the whole house” gadget.
01 — LEAK OVER FREEZE
If both happen, leak wins
Freeze protection keeps that line open and pulses a trickle. A leak on the same line stops the trickle and closes that zone. Built in. Patent pending. Recovers on its own when the probe dries. No setting can turn leak response off.
02 — METERED FREEZE TRICKLE
Design rate: 0.5 gal/hr
At 32°F or below the water stays on. A timed pulse keeps the cold zone moving at Hydra’s design rate of 0.5 gal/hr (1.9 L/hr) — Clemson HGIC 2369’s calculated minimum for an insulated pipe at 15°F — not every faucet running all night.
03 — ZONED LEAK SHUTOFF
Senses water. Shuts that zone.
Moisture sensors find the wet zone and that zone’s valve closes in seconds. The rest of the house keeps water. The main closes as backup if more than one zone is wet.
04 — PRESSURE WATCH
Monitors and alerts. Does not slam the valve.
Line pressure is watched and flagged in the app. A mechanical relief valve handles the physical release. Pressure never closes the main on its own.
Field tested · Little Rock, AR
Outdoor test rig, September 11–16, 2026
Six days. 89,859 readings at two-second intervals. Three independent cold-soak freeze tests. Controlled dry-ice chamber — about 80°F in the yard. Not winter weather.
89,859 readings logged
−11.1°F coldest freeze test
3 independent freeze tests
0 missed leak closures
Three freeze tests, same result. First: 6.46 hours continuous below freezing, unattended, low 10.6°F, trickle duty 10.0% vs 10.0% design, 6,371 of 6,371 readings automatic. Second: independent soak to −11.1°F, Zone 3 trickle ~10.6%, zero overrides. Third: 3.50 hours to 15.8°F, trickle 10.1% both zones. No manual intervention in any of the three.
61.7 hours continuous in one unattended stretch (60,882 samples, 99.995% automatic), including the first freeze plus more than two warm days at 68–103°F. Across that stretch and the full six-day file: every time a monitored line read wet, that line’s valve was closed. Zero exceptions.
Leak still wins mid-freeze. Two leaks staged during the first soak. Both closed that line within one logging cycle — under 4 seconds. The second event had zero manual help.
Open-air test probes can read wet from dew. Hydra still did the right thing: close when wet, reopen when dry, no reset. Sealed sensors are the production fix. This report does not claim a measured trickle gallon rate (timing is measured; the flow sensor is below its accurate range at this pulse) or a pressure result (no calibrated gauge in the loop). Not winter weather. Not a burst test.
Water
3 gal/hr vs 0.5 gal/hr design rate
Clemson’s engineering factsheet (HGIC 2369) calculates an insulated pipe at 15°F needs 0.5 gal/hr. That is Hydra’s design rate. Say design rate — the volume catch test is next.
Open faucet (standard advice)
3 gal/hr
72 gal/day. 216 gal over an assumed 72-hour freeze.
vs
Hydra metered trickle
0.5 gal/hr design rate
12 gal/day. 36 gal over the same 72-hour freeze. One-sixth the water.
180 gallons saved per home over an assumed 72-hour freeze — 681 liters. Timing on the yard rig already matches the 10% design pulse. Volume measurement is the next test.
$30k+ average winter water claim, State Farm, 2024–June 2025. A typical 2-zone Hydra install is $4,000 against that number.
For carriers and freeze-state MGAs
A log you can underwrite. Not a gadget pitch.
Every condition and valve action reports in real time — the same file a carrier can use to verify Hydra is installed and live.
Leak response cannot be turned off. Freeze trickle never closes the main. That arbitration is the product.
$50/month is 24/7 monitoring through the app, plus service visits. Monitoring is not a free add-on.
No named carrier credit and no occupied winter-home install yet. The September 2026 outdoor log is what a first conversation uses.
How it starts
Free remote pre-qual. Paid site visit only to size a real install.
Equipment is $2,500–$6,000 by zone count. A typical 2-zone home is $4,000. $50/month keeps monitoring and service on. Ullur LLC sells Hydra; a carrier credit is the price equalizer — that conversation is open, not closed.
Step 1 — No charge
Free
Remote pre-qual or video walkthrough. We see if the house, the freeze risk, and the zones even fit before anyone drives out.
Step 2 — On-site, if it fits
$500
Paid only when we are sizing a real install. Maps the main, the zones, and the risk points so equipment is right the first time.
Step 3 — Equipment + monitoring
$4,000 typical
Zone valves and leak sensing, metered freeze trickle, carrier-visible app reporting, main-line backup shutoff.
Talk to Ullur LLC
Free remote pre-qual. Or a carrier conversation.
This form is a template — wire it to your mailer when you publish. Homeowners: video walkthrough, no charge. Carriers and MGAs: the September 2026 log and a call. $500 on-site only if we are sizing a real install.