Hydra
A product of Ullur LLC · Little Rock, AR
Fully autonomous, multi-sensor plumbing protection

The freeze-belt risk system insurers can underwrite.

Hydra watches the line and acts without waiting for someone in the house. Zone protection. Metered freeze without an open faucet. Leak always wins. Every action lands in a log a carrier can see.

The risk carriers already pay

Pipes don’t burst because it’s cold. They burst from pressure behind an ice plug. Hydra is freeze and leak on the same line, decided on the device, written to a log. Physics is the mechanism. Risk transfer is the sale.

Open-faucet advice wastes water

The usual advice is to leave a faucet running. That’s about 3 gallons an hour, 72 gallons a day — and it still doesn’t guarantee the pipe won’t freeze.

One winter claim can wipe a year

State Farm paid more than $628 million on 20,000+ frozen-pipe and winter water claims from 2024 through June 2025 — more than $30,000 a claim, one carrier.

Carriers want proof it’s live

Every condition, zone, and action shows in the app as it happens. That same record is how a carrier can verify Hydra is installed and working.

The arbitration

Freeze and leak on the same line. Leak always wins.

Decisions happen on the device. The app is the record — and what the $50/month monitoring buys. This is not an “alert then shut the whole house” gadget.

01 — LEAK OVER FREEZE

If both happen, leak wins

Freeze protection keeps that line open and pulses a trickle. A leak on the same line stops the trickle and closes that zone. Built in. Patent pending. Recovers on its own when the probe dries. No setting can turn leak response off.

02 — METERED FREEZE TRICKLE

Design rate: 0.5 gal/hr

At 32°F or below the water stays on. A timed pulse keeps the cold zone moving at Hydra’s design rate of 0.5 gal/hr (1.9 L/hr) — Clemson HGIC 2369’s calculated minimum for an insulated pipe at 15°F — not every faucet running all night.

03 — ZONED LEAK SHUTOFF

Senses water. Shuts that zone.

Moisture sensors find the wet zone and that zone’s valve closes in seconds. The rest of the house keeps water. The main closes as backup if more than one zone is wet.

04 — PRESSURE WATCH

Monitors and alerts. Does not slam the valve.

Line pressure is watched and flagged in the app. A mechanical relief valve handles the physical release. Pressure never closes the main on its own.

Field tested · Little Rock, AR

Outdoor test rig, September 11–16, 2026

Six days. 89,859 readings at two-second intervals. Three independent cold-soak freeze tests. Controlled dry-ice chamber — about 80°F in the yard. Not winter weather.

89,859 readings logged
−11.1°F coldest freeze test
3 independent freeze tests
0 missed leak closures

Three freeze tests, same result. First: 6.46 hours continuous below freezing, unattended, low 10.6°F, trickle duty 10.0% vs 10.0% design, 6,371 of 6,371 readings automatic. Second: independent soak to −11.1°F, Zone 3 trickle ~10.6%, zero overrides. Third: 3.50 hours to 15.8°F, trickle 10.1% both zones. No manual intervention in any of the three.

61.7 hours continuous in one unattended stretch (60,882 samples, 99.995% automatic), including the first freeze plus more than two warm days at 68–103°F. Across that stretch and the full six-day file: every time a monitored line read wet, that line’s valve was closed. Zero exceptions.

Leak still wins mid-freeze. Two leaks staged during the first soak. Both closed that line within one logging cycle — under 4 seconds. The second event had zero manual help.

Open-air test probes can read wet from dew. Hydra still did the right thing: close when wet, reopen when dry, no reset. Sealed sensors are the production fix. This report does not claim a measured trickle gallon rate (timing is measured; the flow sensor is below its accurate range at this pulse) or a pressure result (no calibrated gauge in the loop). Not winter weather. Not a burst test.

Water

3 gal/hr vs 0.5 gal/hr design rate

Clemson’s engineering factsheet (HGIC 2369) calculates an insulated pipe at 15°F needs 0.5 gal/hr. That is Hydra’s design rate. Say design rate — the volume catch test is next.

Open faucet (standard advice)

3 gal/hr

72 gal/day. 216 gal over an assumed 72-hour freeze.

vs
Hydra metered trickle

0.5 gal/hr design rate

12 gal/day. 36 gal over the same 72-hour freeze. One-sixth the water.

180 gallons saved per home over an assumed 72-hour freeze — 681 liters. Timing on the yard rig already matches the 10% design pulse. Volume measurement is the next test.

$30k+ average winter water claim, State Farm, 2024–June 2025. A typical 2-zone Hydra install is $4,000 against that number.

For carriers and freeze-state MGAs

A log you can underwrite. Not a gadget pitch.

How it starts

Free remote pre-qual. Paid site visit only to size a real install.

Equipment is $2,500–$6,000 by zone count. A typical 2-zone home is $4,000. $50/month keeps monitoring and service on. Ullur LLC sells Hydra; a carrier credit is the price equalizer — that conversation is open, not closed.

Step 1 — No charge

Free

Remote pre-qual or video walkthrough. We see if the house, the freeze risk, and the zones even fit before anyone drives out.

Step 2 — On-site, if it fits

$500

Paid only when we are sizing a real install. Maps the main, the zones, and the risk points so equipment is right the first time.

Step 3 — Equipment + monitoring

$4,000 typical

Zone valves and leak sensing, metered freeze trickle, carrier-visible app reporting, main-line backup shutoff.

Talk to Ullur LLC

Free remote pre-qual. Or a carrier conversation.

This form is a template — wire it to your mailer when you publish. Homeowners: video walkthrough, no charge. Carriers and MGAs: the September 2026 log and a call. $500 on-site only if we are sizing a real install.